Water Filter Certifications Explained: NSF, DVGW, WRAS, ACS
Share this article
On this page
Water filter certifications answer two different questions: what does the filter reduce, and are its materials safe in contact with drinking water? NSF/ANSI 42, 53 and 401 cover the first. NSF/ANSI 372, DVGW and the German UBA criteria, WRAS and ACS mainly cover the second. Knowing which is which makes most filter claims easy to read.
Quick answers
- NSF/ANSI 42: aesthetic effects such as chlorine, taste, odour and particles.
- NSF/ANSI 53: health-related contaminants such as lead, VOCs and cysts.
- NSF/ANSI 401: trace “emerging” compounds such as some medicines and pesticides.
- NSF/ANSI 372: lead content of materials (“lead-free”).
- DVGW / UBA (Germany), WRAS (UK), ACS (France): national approvals, mostly about materials and fittings in contact with drinking water.
- From 31 December 2026: EU-wide positive lists for materials in contact with drinking water start to apply.
Two kinds of standard
| Question | Standards | What a pass tells you |
|---|---|---|
| What does it reduce? | NSF/ANSI 42, 53, 401, 58 (reverse osmosis) | The filter reduced a specific substance by a set amount, over a set number of litres, under test conditions |
| Is it safe to touch the water? | NSF/ANSI 372 and 61, UBA criteria, WRAS, ACS, EU positive lists | The materials don’t release harmful substances into the water above set limits |
A filter can pass a materials approval without being tested for performance at all, and the other way round. So “certified” on its own says very little until you know which standard.
The NSF/ANSI standards
NSF/ANSI standards are American, but they are the most widely used test methods for point-of-use filters worldwide (NSF):
- NSF/ANSI 42 covers non-health contaminants: chlorine, chloramine, taste and odour, particulates, iron, manganese and zinc.
- NSF/ANSI 53 covers health-related contaminants, with over 50 possible claims, including lead, VOCs, chromium and Cryptosporidium.
- NSF/ANSI 401 covers up to 15 trace compounds, such as prescription and over-the-counter drugs, herbicides and pesticides.
- NSF/ANSI/CAN 372 covers the lead content of the materials used.
Each claim is substance by substance. A filter tested to NSF/ANSI 42 for chlorine has not been tested for lead under NSF/ANSI 53, and a lead claim says nothing about PFAS.
“Certified” vs “tested to”
- Certified means an accredited certification body has tested the product, audits the factory, retests it periodically and lists it in a public database.
- Tested to means a laboratory ran the test method in the standard on the product and reported the result. It’s real data, but it’s not a listing, and it isn’t repeated automatically.
Both are legitimate when they are described accurately. What’s not legitimate is calling a product “certified” because one component is, or showing a certification logo for a standard the product was never listed under.
Germany: DVGW and the UBA criteria
In Germany, the Federal Environment Agency (UBA) sets binding evaluation criteria for materials in contact with drinking water under the Drinking Water Ordinance; once issued, they become legally binding after two years (UBA). The DVGW, the German technical association for gas and water, writes technical rules and runs product certification for drinking-water installations; its mark is widely used for fittings and devices sold in Germany.
United Kingdom: WRAS
WRAS approval shows that a material or fitting has been tested to BS 6920 for its effect on water quality and is a common way to show compliance with the UK Water Supply (Water Fittings) Regulations, which apply to fittings connected to the public mains (WRAS). It’s about materials and fittings, not about how much a filter reduces.
France: ACS
The Attestation de Conformité Sanitaire (ACS) is a French certificate of sanitary conformity for products in contact with drinking water, valid for five years. It applies to organic materials and accessories, and to some treatment modules such as ultrafiltration and reverse osmosis, and is required to sell those products in France until the EU rules take over (NSF summary of French regulations).
The EU rules from 31 December 2026
Under the recast Drinking Water Directive, the EU has adopted European positive lists of starting substances and compositions for materials in contact with drinking water: organic, metallic, cementitious and enamel or ceramic materials. They apply from 31 December 2026; until then, national rules such as ACS, the UBA criteria and WRAS-type schemes continue to apply (UL summary of Implementing Decision (EU) 2024/367). Over time this should make a single set of materials rules apply across the EU.
How to read a filter claim in 30 seconds
- Which standard? 42, 53, 401, or a materials standard?
- Which substance? Chlorine, lead, PFAS?
- How much, and over how many litres? “99%” after 50 litres is not “99%” after a year.
- Certified or tested to? And by whom: is the laboratory accredited?
- Can you read the report? If a brand won’t show the data, treat the claim with care.
For more on choosing, see how to choose an under-sink water filter in Europe.
How PJURE describes its own testing
The PJURE under-sink water filter is independently tested to NSF/ANSI 42: at least 97% chlorine reduction through the full 30,000 litres, by an ISO/IEC 17025-accredited laboratory. The same test measured what the KDF® 55 stage releases: copper and zinc stayed under 0.3% of the standard’s limits. The water-contact materials meet NSF/ANSI 372 (lead-free) according to the materials certification. All of it, with the method and the numbers, is in our technical documentation. Read more about the copper-zinc stage in what is KDF® 55?
Frequently asked questions
Which water filter certification matters most?
The one that matches what you want reduced. For chlorine and taste, NSF/ANSI 42. For lead or VOCs, NSF/ANSI 53.
Is NSF certification valid in Europe?
NSF/ANSI standards are test methods, not EU law, but they are widely used in Europe to describe filter performance. Materials rules in Europe are national until the EU positive lists apply from 31 December 2026.
What is the difference between “certified” and “tested to”?
Certified means listed by a certification body with factory audits and retesting. Tested to means a laboratory ran the standard’s method and reported the result.
Does DVGW or WRAS approval mean a filter removes contaminants?
Not on its own. Those approvals are mainly about materials and fittings in contact with water.